EOS2
Table 20. Primary Variables and alternative initial conditions for EOS2
Phase Conditions
PrV1
PrV2
PrV3
PrV4
PrV5
PrV6
Gas
Pg
Pco2
Xtr1
Xtr2
Xtr3
T
Aqueous
Pa
Pco2
Xtr1
Xtr2
Xtr3
T
Two-Phase
Pg
Sg+10
Xtr1
Xtr2
Xtr3
Pco2
Gas
(Alternative)
Pg
Xco2
Xtr1
Xtr2
Xtr3
T
Aqueous
(Alternative
Pa
Xco2
Xtr1
Xtr2
Xtr3
T
Two-phase
(Alternative)
Pg
Sg+10
Xtr1
Xtr2
Xtr3
T
Table 20 shows the parameters of default or alternative initial conditions for EOS2. In the table, Xtrn is tracer n mass fraction in the user specified phase. Xco2 is CO2 mass fraction in existing phase. Pg and Pa are pressure for gas and aqueous phase respectively. T is temperature. Pco2 is CO2 partial pressure. Xtr1-Xtr3 are optional. They are required only when the corresponding tracer component exists in the model.
User can use alternative set parameters as the initial conditions through defining initCType in input data record MODDE.1 or command line –i <parameter>
initCType =
“EOS2” reading the TOUGH3/EOS2 input files.
“SPEOS2” using an alternative set parameter as initial conditions (the last 3 lines, Table 20).