EOS7

Table 24 Primary Variables of EOS7

Phase Conditions

PrV1

PrV2

PrV3

PrV4

PrV5

PrV6

PrV7

PrV8

PrV9

PrV10

Gas

Pg

Xg1

Xg2

Xg3

Xg4

Xbr_G

Xtr1

Xtr2

Xtr3

T

Aqueous

Pa

Xg1

Xg2

Xg3

Xg4

Xbr

Xtr1

Xtr2

Xtr3

T

Two-Phase

Pg

Sg+10

Xg2_G

Xg3_G

Xg4_G

Xbr

Xtr1_G

Xtr2_G

Xtr3_G

T

Two-phase

(Alternative)

Pg

Sg+10

Xg2_A

Xg3_A

Xg4_A

Xbr

Xtr1_A

Xtr2_A

Xtr3_A

T

Table 24 shows the parameters of default and alternative initial conditions for EOS7. In the table, Pg and Pa are pressure for gas and aqueous phase respectively. Xgn and Xtrn are the gas n and tracer n mass fractions in the existing phase, respectively. T is temperature. Xbr is brine mass fraction in aqueous phase. Xgn_G and Xtrn_G are the gas n and tracer n mass fractions in the gas phase excluding water vapor, respectively. Xgn_A and Xtrn_A are the gas n and tracer n mass fractions in the aqueous phase, respectively. Xbr, Xg2-Xg4, Xtr1-Xtr3 are optional. They are required only when the corresponding component exists in the model.

User can use other set parameters as the initial conditions through defining initCType in input data record MODDE.1 or command line –i <parameter>

initCType =

"EOS7" reading the TOUGH3/EOS7 input files.

"EOS7R" reading the TOUGH3/EOS7R input files.

"EOS7C" reading the TOUGH3/EOS7C input files.

"EOS7CA" reading the TOUGH3/EOS7CA input files.

"EOS7MG" reading the TOUGH3/EOS7MG INCON files, 2 lines for each element.

"EOS7MG1L" reading the TOUGH3/EOS7MG INCON files, 1 line for each element.

"SPEOS7” using alternative parameters for two-phase condition (Table 24, last row).

Last updated