EOS9
Table 25. Primary Variables of EOS9
Phase Conditions
PrV1
PrV2
PrV3
PrV4
Saturated Condition
Pw
Xtr1
Xtr2
Xtr3
Unsaturated Condition
Sw
Xtr1
Xtr2
Xtr3
Table 25 shows the parameters of default initial conditions for EOS9. In the table, Xtrn is tracer n mass fraction in the water. Pw is the water pressure. Sw is water saturation. Xtr1-Xtr3 are optional. They are required only when the corresponding tracer component exists in the model. As a special case, the first primary variable may be initialized as PrV1 < 0, in which case it will be taken to denote capillary pressure, and will be converted internally to Swin the initialization phase.
initCType =
“EOS9” reading the TOUGH3/EOS9 input files.