Table 22. Primary Variables of EOS4

Phase Conditions

PrV1

PrV2

PrV3

PrV4

PrV5

PrV6

Gas

Pg

Pair

Xtr1

Xtr2

Xtr3

T

Aqueous

Pa

Pair

Xtr1

Xtr2

Xtr3

T

Two-Phase

Pg

Sg

Xtr1

Xtr2

Xtr3

Pair

Table 22 shows the parameters of default initial conditions for EOS4. In the table, Xtrn is tracer n mass fraction in the user specified phase. Pair is air partial pressure. Pg and Pa are pressure for gas and aqueous phase respectively. Sg is gas saturation. T is temperature. Xtr1-Xtr3 are optional. They are required only when the corresponding tracer component exists in the model.

User can use alternative set parameters as the initial conditions through defining initCType in input data record MODDE.1 or command line –i <parameter>

initCType =

“EOS3” reading the TOUGH3/EOS3 input files.

“EOS4” reading the TOUGH3/EOS4 input files.