RPCAP

RPCAP introduces information on relative permeability and capillary pressure functions, which will be applied for all flow domains for which no data were specified in records ROCKS.1.2 and ROCKS.1.3. A catalog of relative permeability and capillary pressure functions is presented in Appendix A and Appendix B, respectively.

Record RPCAP.1

Free format for 11 parameters, or Format (I5,5X,10E10.4)

IRP, (RP(I), I = 1, 10)

IRP integer parameter to choose type of relative permeability function (see Appendix A).

RP(I) I = 1, ..., 10 parameters for relative permeability function (Appendix A). I=8-10 are required only for IRP=12.

Record RPCAP.2

Free format for 14 parameters, or Format (I5,5X,13E10.4)

ICP, (CP(I), I = 1, 13)

ICP integer parameter to choose type of capillary pressure function (see Appendix B).

CP(I) I = 1, ..., 13 parameters for capillary pressure function (Appendix B). I=8-13 are required only for ICP=12.

Used in: All EOS modules

Example:

RPCAP

12, 0.917, 0.200, 0.200, 0.333, 1.000, 0.00, 0.97 // relative permeability function 12

12, 0.412, 0.030, 4.e3, 4.e5, 1.0, 0.412, 4.e3, 0.98, 0.0, 1.0e-06, 0.02, 0.0 // CAP function 12